Calibration of a white light interferometer for the measurement of micro-scale dimensions


Reference:

Ferri, C., Faraway, J. and Brousseau, E., 2010. Calibration of a white light interferometer for the measurement of micro-scale dimensions. The International Journal of Advanced Manufacturing Technology, 47 (1-4), pp. 125-135.

This is the latest version of this item.

Related documents:

[img]
Preview
Postscript (calibration.ps) - Requires a viewer, such as GSview
Download (3288kB) | Preview
    [img]
    Preview
    PDF (calibration.pdf) - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
    Download (521kB) | Preview
      [img] Other (calibration.dvi)
      Download (113kB)

        Official URL:

        http://dx.doi.org/10.1007/s00170-009-2050-7

        Abstract

        Calibration is central to most measurement procedures. This is especially true in those cases where a large number of difficult-to-identify and difficult-to-control factors hinder the experimenters in their efforts to obtain reliable measurement results. Dimensional measurements of features on the micro- and nano-scales is one such case. A white-light interferometer (WLI) microscope can perform measurements of a variety of measurands over a broad dimensional range: from surface texture characterisations on the nano-scale to measurements of step heights of several millimetres. Calibration methods based on the hypothesis of a linear calibration curve can be inadequate to express the relationship between measurement results and traceable reference materials (RMs). A calibration procedure built into a commercially available WLI microscope is critically compared with methods presented in an international standard. This comparison is enabled by a cost-effective procedure for establishing traceable RMs in the micro-range. Advantages of calibration procedures based on more than one RM are then demonstrated within the ranges from 180.5 to 219.5 μm and from 1.5 to 501.5 μm. Calibration methods involving regression modelling of transformed measurement results are considered for these two intervals to overcome the highlighted weaknesses of the calibration procedure built in the examined WLI.

        Details

        Item Type Articles
        CreatorsFerri, C., Faraway, J. and Brousseau, E.
        DOI10.1007/s00170-009-2050-7
        Uncontrolled Keywordswli, white light interferometry, regression analysis, calibration
        DepartmentsFaculty of Science > Mathematical Sciences
        Faculty of Engineering & Design > Mechanical Engineering
        Research CentresInnovative Design & Manufacturing Research Centre (IdMRC)
        Publisher Statementcalibration.ps: The original publication is available at www.springerlink.com; calibration.pdf: The original publication is available at www.springerlink.com; calibration.dvi: The original publication is available at www.springerlink.com
        RefereedYes
        StatusPublished
        ID Code14280
        Additional InformationThis is the peer-reviewed author-created self-archived version of the manuscript. The publisher's PDF version posted at http://dx.doi.org/10.1007/s00170-009-2050-7 differs from this in some minor language adjustments and in formatting.

        Export

        Available Versions of this Item

        Actions (login required)

        View Item

        Document Downloads

        More statistics for this item...