Research

Analysis of wear of retrieved metal-on-metal hip resurfacing implants revised due to pseudotumours


Reference:

Kwon, Y. M., Glyn-Jones, S., Simpson, D. J., Kamali, A., McLardy-Smith, P., Gill, H. S. and Murray, D. W., 2010. Analysis of wear of retrieved metal-on-metal hip resurfacing implants revised due to pseudotumours. Journal of Bone and Joint Surgery - British Volume, 92 (3), pp. 356-361.

Related documents:

This repository does not currently have the full-text of this item.
You may be able to access a copy if URLs are provided below. (Contact Author)

Official URL:

http://10.1302/0301-620X.92B3.23281

Related URLs:

Abstract

The presence of pseudotumours, which are soft-tissue masses relating to the hip, after metal-on-metal hip resurfacing arthroplasty has been associated with elevated levels of metal ions in serum, suggesting that pseudotumours occur when there is increased wear. We aimed to quantify the wear in vivo of implants revised for pseudotumours (eight) and of a control group of implants (22) revised for other reasons of failure. We found that the implant group with pseudotumours had a significantly higher rate of median linear wear of the femoral component at 8.1 microm/year (2.75 to 25.4) than the 1.79 microm/year (0.82 to 4.15; p = 0.002) of the non-pseudotumour group. For the acetabular component a significantly higher rate of median linear wear of 7.36 microm/year (1.61 to 24.9) was observed in the pseudotumour group compared with 1.28 microm/year (0.81 to 3.33, p = 0.001) in the other group. Wear of the acetabular component in the pseudotumour group always involved the edge of the implant, indicating that edge-loading had occurred. Our findings are the first direct evidence that pseudotumour is associated with increased wear at the metal-on-metal articulation. Furthermore, edge-loading with the loss of fluid-film lubrication may be an important mechanism of generation of wear in patients with a pseudotumour.

Details

Item Type Articles
CreatorsKwon, Y. M., Glyn-Jones, S., Simpson, D. J., Kamali, A., McLardy-Smith, P., Gill, H. S. and Murray, D. W.
DOI10.1302/0301-620X.92B3.23281
Related URLs
URLURL Type
http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=20190305PubMedCentral
DepartmentsFaculty of Engineering & Design > Mechanical Engineering
Research CentresCentre for Orthopaedic Biomechanics
RefereedYes
StatusPublished
ID Code30779

Export

Actions (login required)

View Item