Research

Retention of arthroscopic shoulder skills learned with use of a simulator : Demonstration of a learning curve and loss of performance level after a time delay


Reference:

Howells, N. R., Auplish, S., Hand, G. C., Gill, H. S., Carr, A. J. and Rees, J. L., 2009. Retention of arthroscopic shoulder skills learned with use of a simulator : Demonstration of a learning curve and loss of performance level after a time delay. Journal of Bone and Joint Surgery, American Volume, 91 (5), pp. 1207-1213.

Related documents:

This repository does not currently have the full-text of this item.
You may be able to access a copy if URLs are provided below. (Contact Author)

Official URL:

http://dx.doi.org/10.2106/JBJS.H.00509

Related URLs:

Abstract

BACKGROUND: In orthopaedic surgery, arthroscopy is an irreplaceable diagnostic and interventional tool, and its breadth of use is increasing. The aim of this study was to investigate the surgeon's capacity for retention of an unfamiliar arthroscopic skill. METHODS: Six fellowship-trained lower-limb surgeons were given standardized instruction regarding the performance of an arthroscopic Bankart suture on a laboratory-based simulator. They performed three single Bankart sutures on each of four occasions, one to two weeks apart. Six months later, the same surgeons repeated the study. They received no further instruction or guidance. Their performance was objectively assessed with use of validated motion-analysis equipment to record the total path length of the surgeon's hands, number of hand movements, and time taken to perform the sutures. RESULTS: A learning curve showing significant and objective improvement in performance was demonstrated for all outcome parameters in both experiments (p <0.005). The learning curve at six months was a repeated learning curve showing no significant difference from the initial learning curve. CONCLUSIONS: This study objectively demonstrated a loss of all of the initial improvement in the performance of an arthroscopic Bankart suture following a six-month interval in which the surgeons did not do the procedure.

Details

Item Type Articles
CreatorsHowells, N. R., Auplish, S., Hand, G. C., Gill, H. S., Carr, A. J. and Rees, J. L.
DOI10.2106/JBJS.H.00509
Related URLs
URLURL Type
http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=19411470PubMedCentral
DepartmentsFaculty of Engineering & Design > Mechanical Engineering
Research CentresCentre for Orthopaedic Biomechanics
RefereedYes
StatusPublished
ID Code30797

Export

Actions (login required)

View Item