Research

Transmission line modelling with vaporous cavitation


Reference:

Shu, J., Edge, K. A., Burrows, C. R. and Xiao, S., 1993. Transmission line modelling with vaporous cavitation. In: ASME WAM, 1993-01-01, New Orleans, LA.

Related documents:

This repository does not currently have the full-text of this item.
You may be able to access a copy if URLs are provided below.

Abstract

A comprehensive study of the problem of modelling vaporous cavitation in transmission lines is presented. The two-phase homogeneous equilibrium vaporous cavitation model which has been developed is compared with the conventional column separation model. The latter predicts unrealistically high pressure spikes because of a conflict arising from the prediction of negative cavity sizes if the pressure is not permitted to fall below the vapour pressure, or the prediction of negative absolute pressures if the cavity size remains positive. This is verified by a comparison of predictions with previously-published experimental results on upstream, midstream and downstream cavitation. The new model has been extended to include frequency-dependent friction. The characteristics predicted by the frequency-dependent friction model show close correspondence with experimental data

Details

Item Type Conference or Workshop Items (Paper)
CreatorsShu, J., Edge, K. A., Burrows, C. R. and Xiao, S.
DepartmentsFaculty of Engineering & Design > Mechanical Engineering
University Administration & Central Services > Vice-Chancellor's Office
RefereedNo
StatusPublished
ID Code3207

Export

Actions (login required)

View Item