2013

Ruther, C., Nierath, H., Ewald, H., Cunningham, J.L., Mittelmeier, W., Bader, R. and Kluess, D., 2013. Investigation of an acoustic-mechanical method to detect implant loosening. Medical Engineering & Physics, 35 (11), pp. 1669-1675.

Bone, M. C., Cunningham, J. L., Lord, J., Giddins, G., Field, J. and Joyce, T. J., 2013. Analysis of failed Van Straten LPM proximal interphalangeal prostheses. Journal of Hand Surgery-European Volume, 38 (3), pp. 313-320.

2012

Brampton, C.J., Kim, H. A. and Cunningham, J.L., 2012. Level set topology optimisation of aircraft wing considering aerostructural interaction. In: 12th AIAA Aviation Technology, Integration and Operations (ATIO) Conference and 14th AIAA/ISSMO Multidisciplinary Analysis and Optimization Conference. American Institute of Aeronautics and Astronautics.

Brampton, C. J., Kim, A. H. and Cunningham, J. L., 2012. Algorithm to maintain linear element in 3D level set topology optimization. In: ICPRAM 2012 - Proceedings of the 1st International Conference on Pattern Recognition Applications and Methods. , pp. 341-350.

Brampton, C. J., Kim, H. A. and Cunningham, J. L., 2012. Applications of 3D level set topology optimization. In: ASME 2012 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference. Vol. 3 . Chicago, IL: ASME, pp. 875-882.

2010

Meswania, J. M., Bousdras, V. A., Ahir, S. P., Cunningham, J. L., Blunn, G. W. and Goodship, A. E., 2010. A novel closed-loop electromechanical stimulator to enhance osseointegration with immediate loading of dental implant restorations. Proceedings of the Institution of Mechanical Engineers, Part H - Journal of Engineering in Medicine, 224 (10), pp. 1221-1231.

2009

Gheduzzi, S., Dodd, S. P., Miles, A. W., Humphrey, V. F. and Cunningham, J. L., 2009. Numerical and experimental simulation of the effect of long bone fracture healing stages on ultrasound transmission across an idealized fracture. Journal of the Acoustical Society of America, 126 (2), pp. 887-894.

Eastaugh-Waring, S. J., Joslin, C. C., Hardy, J. R. W. and Cunningham, J., 2009. Quantification of Fracture Healing from Radiographs Using the Maximum Callus Index. Clinical Orthopaedics and Related Research, 467 (8), pp. 1986-1991.

Kim, H. A., Howard, G. J. and Cunningham, J. L., 2009. Do trabeculae of femoral head represent a structural optimum? In: Lim, C. T. and Goh, G. T. C., eds. 13th International Conference on Biomedical Engineering. Vol. 23. Springer, pp. 1636-1639. (IFMBE Proceedings)

Cunningham, J. L., 2009. Development of degrees in medical engineering at the University of Bath. Proceedings of the Institution of Mechanical Engineers, Part H - Journal of Engineering in Medicine, 223 (H4), pp. 437-441.

Claes, L. E. and Cunningham, J., 2009. Monitoring the mechanical properties of healing bone. Clinical Orthopaedics and Related Research, 467 (8), pp. 1964-1971.

2008

Clements, J. P., Moriaty, N., Chesser, T. S., Ward, A. J. and Cunningham, J. L., 2008. Determination of pelvic ring stability: a new technique using a composite hemi-pelvis. Proceedings of the Institution of Mechanical Engineers, Part H - Journal of Engineering in Medicine, 222 (5), pp. 611-616.

Dodd, S. P., Cunningham, J. L., Miles, A. W., Gheduzzi, S. and Humphrey, V. F., 2008. Ultrasound transmission loss across transverse and oblique bone fractures: an in-vitro study. Ultrasound in Medicine & Biology, 34 (3), pp. 454-462.

Joslin, C. C., Eastaugh-Waring, S. J., Hardy, J. R. W. and Cunningham, J. L., 2008. Weight bearing after tibial fracture as a guide to healing. Clinical Biomechanics, 23 (3), pp. 329-333.

Rowlands, A., Duck, F. and Cunningham, J. L., 2008. Bone vibration measurement using ultrasound; application to detection of hip prosthesis loosening. Medical Engineering & Physics, 30 (3), pp. 278-284.

Cunningham, J., Tudor, J. J. T. and Hughes, N., 2008. Can acetabular component loosening be determined using a vibrational technique? In: Proc.14th Annual Scientific Meeting, Institute of Physics and Engineering in Medicine, 2008-01-01.

Kim, H. A., Clement, P. J. and Cunningham, J. L., 2008. Investigation of cancellous bone architecture using structural optimisation. Journal of Biomechanics, 41 (3), pp. 629-635.

Humphrey, V. F., Dodd, S. P., Gheduzzi, S., Cunningham, J. L. and Miles, A. W., 2008. Numerical modelling and in-vitro studies of ultrasound signal loss across fractures in cortical bone mimics. Journal of the Acoustical Society of America, 123 (5), p. 3514.

2007

Cunningham, J. L., Clement, P. J. and Kim, H. A., 2007. Cancellous bone architecture as a structural optimum. In: 7th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering, 2007-03-01, Cote D'Azur.

Vickerstaff, J. A., Miles, A. W. and Cunningham, J. L., 2007. A brief history of total ankle replacement and a review of the current status. Medical Engineering & Physics, 29 (10), pp. 1056-1064.

Dodd, S. P., Cunningham, J. L., Miles, A. W., Gheduzzi, S. and Humphrey, V. F., 2007. An in vitro study of ultrasound signal loss across simple fractures in cortical bone mimics and bovine cortical bone samples. Bone, 40 (3), pp. 656-661.

Mak, S., Cunningham, J. L. and Miles, A. W., 2007. Determination of Poisson's ratio and hoop strain of morsellised bone graft under uni-axial compressive loading. In: Transactions 53rd Annual Meeting of the Orthopaedic Research Society, 2007-01-01.

Mak, S. Y., Cunningham, J. L. and Miles, A. W., 2007. Elastic modulus and stress-strain characteristics of morsellised bone graft under different loading conditions. In: Transactions 6th Combined Meeting of the Orthopaedic Research Societies, 2007-01-01.

Bousdras, V. A., Sindert-Pedersen, S., Cunningham, J. L., Blunn, G., Petrie, A., Naert, I. E., Jaecques, S. and Goodship, A. E., 2007. Immediate Functional Loading of Single-Tooth TIO Grit-Blasted Implant Restorations: A Controlled Prospective Study in a Porcine Model. Part I: Clinical Outcome. Clinical Implant Dentistry and Related Research, 9 (4), pp. 197-206.

Bousdras, V. A., Walboomers, F., Jansen, J. A., Cunningham, J. L., Blunn, G., Petrie, A., Jaecques, S., Naert, I. A., Sindert-Pedersen, S. and Goodship, A. E., 2007. Immediate Functional Loading of Single-Tooth TiO(2) Grit-Blasted Implant Restoration. A Controlled Prospective Study in a Porcine Model. Part II: Histology and Histomorphometry. Clinical Implant Dentistry and Related Research, 9 (4), pp. 207-216.

Dodd, S. P., Miles, A. W., Gheduzzi, S., Humphrey, V. F. and Cunningham, J. L., 2007. Modelling the effects of different fracture geometries and healing stages on ultrasound signal loss across a long bone fracture. Computer Methods in Biomechanics and Biomedical Engineering, 10, pp. 371-375.

Cunningham, J. L., Bisbinas, I., Greenwood, R. and Learmonth, I. D., 2007. Precision of wear measurement using the shadowgraph technique. Proceedings of the Institute of Mechanical Engineering, Part H: Journal of Engineering in Medicine, 221, pp. 899-902.

Mak, S. Y., Cunningham, J. L. and Miles, A. W., 2007. The effect on rate of impaction on morsellised bone graft. In: Transactions 6th Combined Meeting of the Orthopaedic Research Societies, 2007-01-01.

2006

Bousdras, V. A., Cunningham, J. L., Ferguson-Pell, M., Bamber, M. A., Sindet-Pedersen, S., Blunn, G. and Goodship, A. E., 2006. A novel approach to bite force measurements in a porcine model in vivo. Interational Journal of Oral & Maxillofacial Surgery, 35, pp. 663-667.

Bisbinas, I., Tripsianis, G., Cunningham, J. L. and Learmonth, I. D., 2006. A radiological and laboratory assessment of polyethylene wear in failed total hip replacement. Hip International, 16 (1), pp. 39-46.

Kim, H. A., Clement, P. and Cunningham, J. L., 2006. Stress-based optimum and bone architecture. In: III European Conference on Computational Mechanics - Solids, Structures and Coupled Problems in Engineering, 2006-01-01, Lisbon.

2005

Cunningham, J. L., Clement, P. J. and Kim, H. A., 2005. Bone as Fully Stressed Design. In: European Society of Biomechanics Thematic Workshop: Mechanobiology of Cells and Tissue Regeneration, 2005-08-01, Leuven.

Reddy, V. R. M., Miles, A. W., Cunningham, J. L., Gheduzzi, S. and Henman, P., 2005. Comparison of biomechanical properties of flexible steel and titanium intramedullary nails in adolescent fractures. In: Journal of Bone and Joint Surgery - British Volume, 2005-06-01, Lisbon.

Bousdras, V., Cunningham, J. L., Bamber, M. A., Ferguson-Pell, M., Blunn, G., Sindet-Pedersen, S. and Goodship, A. E., 2005. Bite force measurements on natural and implant restored teeth in a porcine model in vivo: a preliminary report. Journal of Maxillofacial Prosthetics & Technology, 8 (1), pp. 4-7.

Cunningham, J. L., Smith, T. J., Blunn, G. W. and Goodship, A. E., 2005. Following damage, trabecular architecture is not restored by functional loading. In: Transactions 51st Annual Meeting of the Orthopaedic Research Society, 2005-01-01.

Coathup, M. J., Blackburn, J., Goodship, A. E., Cunningham, J. L., Smith, T. and Blunn, G. W., 2005. Role of hydroxyapatite coating in resisting wear particle migration and osteolysis around acetabular components. Biomaterials, 26 (19), pp. 4161-4169.

Blom, A. W., Cunningham, J. L., Hughes, G., Lawes, T. J., Smith, N., Blunn, G., Learmonth, I. D. and Goodship, A. E., 2005. The compatibility of ceramic bone graft substitutes as allograft extenders for use in impaction grafting of the femur. Journal of Bone and Joint Surgery - British Volume, 87B (3), pp. 421-425.

2004

Dodd, S. P., Cunningham, J. L., Miles, A. W., Humphrey, V. F. and Gheduzzi, S., 2004. Ultrasonic wave propagation in cortical bone mimics. In: 148th Meeting of the Acoustical Society of America, 2004-11-15 - 2004-11-19, San Diego, CA.

Gheduzzi, S., Humphrey, V. F., Dodd, S. P., Cunningham, J. L. and Miles, A. W., 2004. Ultrasound attenuation as a quantitative measure of fracture healing. In: 148th Meeting of the Acoustical Society of America, 2004-11-15 - 2004-11-19, San Diego, CA.

Cunningham, J. L., 2004. Vibration analysis. In: The Physical Measurement of Bone. Bristol and Philadelphia: Institute of Physics Publishing, pp. 511-547.

2003

Vadivelu, R., Drew, S. J., Baker, A. S., Miles, A. W., Gheduzzi, S., Cunningham, J. L. and Chetwynd, D. G., 2003. Bio-mechanical comparison of four different forms of fixation used for two-part proximal humeral fractures. Injury, 34 (8), p. 599.

Harrison, L. J., Cunningham, J. L., Stromberg, L. and Goodship, A. E., 2003. Controlled induction of a pseudarthrosis: A study using a rodent model. Journal of Orthopaedic Trauma, 17 (1), pp. 11-21.

Eldridge, J. D. J., Cunningham, J. L., Samuels, A., Blunn, G. W., Lawes, T. J., Learmonth, I. D. and Goodship, A. E., 2003. Glass ionomer as an expander of allograft in revision arthroplasty of the hip. Biomaterials, 24 (3), pp. 499-508.

2002

Vadivelu, R., Baker, A. S., Miles, A. W., Gheduzzi, S., Cunningham, J. L. and Chetwynd, D., 2002. A mechanical comparison of dynamic compression plate, limited contact dynamic compression plate and the fixclips. In: Meeting of the British Trauma Society, 2003-01-01.

Leonard, L., Sirkett, D. M., Langdon, I. J., Mullineux, G., Tilley, D. G., Keogh, P. S., Cunningham, J. L., Cole, M. O. T., Prest, P. H., Miles, A. W. and Giddins, G. E. B., 2002. Engineering a new wrist joint replacement prosthesis - A multidisciplinary approach. Proceedings of the Institution of Mechanical Engineers, Part B: Journal of Engineering Manufacture, 216 (9), pp. 1297-1302.

Vadivelu, R., Baker, A. S., Miles, A. W., Cunningham, J. L., Gheduzzi, S. and Chetwynd, D., 2002. A biomechanical study of dynamic compression plate, limited contact dynamic compression plate and the fixclips. In: 12th Annual Meeting of the European Orthopaedic Research Society, 2002-01-01, Lausanne.

Langdon, I. J., Leonard, L., Tilley, D. G., Keogh, P. S., Cole, M. O. T., Cunningham, J. L., Miles, A. W. and Giddins, G. E. B., 2002. A simulator for evaluation of total wrist arthroplasties. In: British Orthopaedic Research Society, 2002-01-01, Cardiff.

Langdon, I. J., Leonard, L., Tilley, D. G., Cunningham, J. L., Giddins, G. E. B. and Miles, A. W., 2002. A simulator to investigate load transfer between implant and bone for wrist arthroplasty. In: SICOT Trainees Meeting, 2002-01-01, St Petersburg, Russia.

Langdon, I. J., Leonard, L., Tilley, D. G., Keogh, P. S., Cole, M. O. T., Cunningham, J. L., Miles, A. W. and Giddins, G. E. B., 2002. Development of a wrist simulator. In: European Society of Biomechanics Meeting, 2002-01-01, Poland.

Blom, A. W., Grimm, B., Cunningham, J., Miles, A. W. and Learmonth, I. D., 2002. In-vitro testing of BoneSave, a ceramic bone graft substitute for use in impaction grafting. In: Bioceramics 14, 2002-01-01.

Armstrong, M. S., Spencer, R. F., Cunningham, J. L., Gheduzzi, S., Miles, A. W. and Learmonth, I. D., 2002. Mechanical characteristics of antibiotic-laden bone cement. Acta Orthopaedica Scandinavica, 73 (6), pp. 688-690.

Blom, A. W., Grimm, B., Miles, A. W., Cunningham, J. L. and Learmonth, I. D., 2002. Subsidence in impaction grafting: the effect of adding a ceramic bone graft extender to bone. Proceedings of the Institution of Mechanical Engineers, Part H - Journal of Engineering in Medicine, 216 (H4), pp. 265-270.

Gheduzzi, S., Cunningham, J. L., Humphrey, V. F. and Miles, A. W., 2002. Ultrasound propagation in long bones as quantative measure of fracture healing. In: British Orthopaedic Research Society, 2002-01-01, Cardiff.

2001

Spencer, R. F., Armstrong, M., Cunningham, J. L., Gheduzzi, S., Miles, A. W. and Learmonth, I. D., 2001. Mechanical characteristics of antibiotic-laden bone cement. In: 5th Congress of EFORT, 2001-06-01, Rhodes.

Gheduzzi, S., Humphrey, V. F., Cunningham, J. L. and Miles, A. W., 2001. A novel use of quantitative ultrasound for the monitoring of fracture healing in human long bones.

Gheduzzi, S., Miles, A. W., Humphrey, V. F. and Cunningham, J. L., 2001. In-vitro evaluation of quantitative ultrasound as a clinical tool for fracture healing assessment in human long bones. In: 47th Annual Meeting of the Orthopaedic Research Society, 2001-02-25 - 2001-02-28, San Francisco, CA.

Georgiou, A. P. and Cunningham, J. L., 2001. Accurate diagnosis of hip prosthesis loosening using a vibrational technique. Clinical Biomechanics, 16 (4), pp. 315-323.

Karnezis, I. A., Fragkiadakis, E. G., Panagiotopolous, E., Miles, A. W. and Cunningham, J. L., 2001. Biomechanics of a new uniform-pitch headless screw for minimally-invasive osteosynthesis. In: 5th Congress of EFORT, 2001-06-01, Rhodes.

Karnezis, I. A., Drosos, D., Fragkiadakis, E. G., Panagiotopolous, E., Vossinakis, I. C., Cunningham, J. L. and Miles, A. W., 2001. Biomechanics of non-contact plating of diaphyseal fractures - a biomechanical study using simulated fracture healing. In: 5th Congress of EFORT, 2001-06-01, Rhodes.

Eldridge, J. D. J., Cunningham, J. L., Samules, A., Lawes, T. J., Learmonth, I. D. and Goodship, A. E., 2001. Glass ionomer as a potential osteoconductive expander of allograft in revision arthroplasty of the hip. Advances in Composite Materials and Structures, Parts 1 and 2, 192-195, pp. 951-954.

Gheduzzi, S., Miles, A. W., Humphrey, V. F. and Cunningham, J. L., 2001. In vitro evaluation of quantitative ultrasound as a clinical tool for fracture healing assessment in human long bones. In: Transactions 50th Orthopaedic Research Society, 2004-01-01, San Francisco.

Blom, A. W., Grimm, B., Miles, A. W. and Cunningham, J. L., 2001. Mechanical studies on a ceramic bone graft substitute for use in revision total hip arthroplasty. In: 5th Congress of EFORT, 2001-06-01, Rhodes.

Goodship, A. E. and Cunningham, J. L., 2001. Pathophysiology of functional adaptation of bone in remodelling and repair in-vivo. In: Bone Mechanics Handbook (2nd Ed.). Boca Raton, London, New York, Washington D.C.: CRC Press, 26.1-26.31.

Cunningham, J. L., 2001. The biomechanics of fracture fixation. Current orthopaedics, 15 (6), pp. 457-464.

Blom, A. W., Cunningham, J. L., Laws, T. J., Hughes, G., Goodship, A. E. and Learmonth, I. D., 2001. Tricalcium phosphate/hydroxyapatite mixtures as bone allograft expanders in revision total hip arthroplasty of the femur: an ovine study. Advances in Composite Materials and Structures, Parts 1 and 2, 192-195, pp. 377-382.

2000

Gheduzzi, S., Cunningham, J. L., Miles, A. W. and Humphrey, V. F., 2000. Feasibility of fracture healing measurement using ultrasound velocity and attenuation.

Gheduzzi, S., Cunningham, J. L., Miles, A. W. and Humphrey, V. F., 2000. A computational model of ultrasound propagation in fractured human long bones. In: International Society for Fracture Repair Meeting, 2000-09-01, Hong Kong.

Gheduzzi, S., Miles, A. W., Humphrey, V. F. and Cunningham, J. L., 2000. Long bones fracture healing assessed by quantitative ultrasound. In: Int Society for Fracture Repair (ISFR), 2000-01-01, Hong Kong.

1999

Gheduzzi, S., Humphrey, V. F., Miles, A. W. and Cunningham, J. L., 1999. Fracture healing assessment using ultrasound velocity and attenuation.

Gheduzzi, S., Cunningham, J. L., Miles, A. W. and Humphrey, V. F., 1999. Fracture healing measurement using ultrasound. In: Physics and Technology of Mechanical Ultrasound, 1999-01-01, York.

1997

Goodship, A. E., Cunningham, J. L., Walker, P., Organov, V., Darling, J., Miles, A. W. and Owen, G. W., 1997. Bone loss during long term space flight is prevented by the application of a short term impulsive mechanical stimulus. In: 12th Man in Space Symposium, 1997-06-01, Washington.

Karnezis, I. A., Miles, A. W., Cunningham, J. L. and Learmonth, I. D., 1997. The effect of axial preload on the preformance of external fixator pins - a mechanical study using a new bone fastener system. In: Autumn Meeting of British Orthopaedic Research Society, 1997-01-01, Cardiff.

1991

Evans, M., White, S. H. and Cunningham, J. L., 1991. Improvement in the design of bone screws for external fixation. In: Interfaces in Medicine and Mechanics - 2., 1991-01-01, Amsterdam.

White, S. H., Cunningham, J. L., Richardson, J. B., Evans, M., Kenwright, J., Adams, M. A., Goodship, A. E., Smith, E. and Newman, J. H., 1991. Improvement of fracture healing by applied axial micromovement: A clinical study. In: Interfaces in Medicine and Mechanics - 2., 1991-01-01, Amsterdam.

1989

Cunningham, J. L., Evans, M. and Kenwright, J., 1989. Mechanical Measurements of Fracture Repair. In: The Changing Role of Engineering in Orthopedics, 1989-04-14 - 1989-04-15, London.